| Address: Sahibabad, Pargana- Loni, Tehsil- Ghaziabad, District- Ghaziabad.Part, C-12 Shalimar Garden Extension-02, Near Gaur Chowk opposite Mutthoot Finance Sahibabad Ghaziabad, 201005 |
To,
The vice chairman,
Ghaziabad development authority
Ghaziabad (Uttar pradesh).
I would like to bring your kind attention on the illegal construction taking place. As we stop them so many times to don't do illegal construction, they didn’t listened us and making five stories unauthorized building and constructions is continue. So, i request you to come to this address (Sahibabad, pargana - loni, tehsil - ghaziabad, district - ghaziabad. Part, c-12 shalimar garden extension-02, near gaur chowk opposite mutthoot finance sahibabad ghaziabad to see the construction and stop this at the earliest.
Here, everyone in mig, hig and lig flat and double commercial shops and offices construction and modify their balcony boundaries and iron bars cage extended to four or five feet on road unauthorised, now road and government land is using by these two roads resident for their own use no one can use this as a public and citizen of democratic of india, have you seen (Sahibabad, pargana - loni, tehsil - ghaziabad, district - ghaziabad. Part, c-12 shalimar garden extension-02, near gaur chowk opposite mutthoot finance sahibabad ghaziabad, who opened there walls in front and back side, extended too much. Side buildings are low rise where individual cannot survive safely their live due to this high-rise building.
(Sahibabad, pargana - loni, tehsil - ghaziabad, district - ghaziabad. Part, c-12 shalimar garden extension-02, near gaur chowk opposite mutthoot finance sahibabad ghaziabad flats and commercial shops are totally without any fire compliances there no ant fire fighting equipments and without any fire department permission no approval is with them.
(Sahibabad, pargana - loni, tehsil - ghaziabad, district - ghaziabad. Part, c-12 shalimar garden extension-02, near gaur chowk opposite mutthoot finance sahibabad ghaziabad flats and shops are totally demolished by private contractor, without permission no approval is with them, this work was so noisy that we cannot sleep a bit, day and night these hammers are going on. Submersible motor is banned but this resident is placed submersible connection in open govt. Land and on road. Provisions for sustainable methods of water and wastewater management, and water harvesting.
(Sahibabad, pargana - loni, tehsil - ghaziabad, district - ghaziabad. Part, c-12 shalimar garden extension-02, near gaur chowk opposite mutthoot finance sahibabad ghaziabad, they are constructing whole building, the work is going on from last eight nine months but no one is looking for that. No one can drive from here as the construction material placed on roads. Please help me and i am social worker. I am doing social service. Plz help.
Provisions for high rise development:-
Buildings higher than 15m of height without stilts and above 17.5m of height with stilts shall be considered as high rise building.
Plot area plots to be used for high rise development should be located in an approved layout plan, comprehensive plans or sub division plans as prepared and approved by competent authorities/ as per policy of the government of india / state governments.
Means of access:-
1. A building shall abut on a street or streets or upon spaces directly connected from the street by a hard surface approach road; width of approach road is not less than 9 meters,
2. If there are any bends or curves on the approach road, a sufficient width shall be provided at the curve to enable the fire appliances to turn, the turning circle being at least of 9.0 m radius. Where entry to the plot is through a slip road the gate width shall not be less than 6 m for entry of the fire fighting appliance.
3. The approach road to the building and open spaces on its all sides up to 6 m width and the layout for the same shall be done in consultation with chief fire officer, fire service and the same shall be reinforced to ensure safety of the fire equipment and capable of taking the weight of fire engine, weighing up to 45 tonnes) the said open space shall be kept free of obstructions and shall be motor able.
4. Main entrances to the premises shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 6 m. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire service vehicles. If archway is provided over the main entrance the height of the archway shall not be at a height less than 5m.
5. For multi-storeyed schemes on one plot, the approach road to the site shall be minimum 18 m in width.
Peripheral open spaces including setbacks: - there shall be a space of 6 m all around up to 40m height and after that a space of 9m all around should be provided
Parking spaces:-the parking spaces shall be provided as per the provisions of master plan or zonal plan as prevalent. The location of parking spaces shall be well ventilated.
In case of high-rise buildings parking will be permitted at any / all of the following:-
I. Basements
Ii. Stilts
Iii. Podium
Iv. Stacked/ multi-level/ automated parking is also permitted.
Doorways:-
1. Every doorway shall open into an enclosed stairway, a horizontal exit, on a corridor or passageway providing continuous and protected means of egress.
2. No exit doorway shall be less than 1m in width. Doorways shall be not less than 2 m in height. Doorways for bathrooms, water closet, stores etc. Shall be not less than 0.75m wide.
3. Exit door shall not open immediately upon a flight or stairs, a landing equal to at least the width of the door shall be provided in the stairway at each doorway, level of landing shall be the same as that of the floor which it serves.
General guidance for water supply arrangements :-
1. For new construction: provision shall be made for underground tank for the storage of water, having capacity at 200 ltr. Per person with adequate pumping arrangements to supply water to upper floors. Filtered water connection will be allowed only for use of drinking and bathing needs. For other purposes i. E. Flushing and gardening etc., the individual shall be required to have own arrangements of tube well water within the premises. While according sanction to layout plan, the authority shall make a special mention that provision for space shall be kept for the construction o[censored]nderground reservoir of adequate capacity along with booster pumping station.
2. Arrangements as given in 1 above shall also be provided in group housing societies.
3. The plumbing arrangement in case of new constructions shall be made in a way that the potable water shall be used for drinking, cooking & bathing only and for rest of the uses, provision for ground water can be made with dual piping system.
4. Low capacity cistern should preferably be provided instead of normal 12.5 l capacity.
5. Provisions for sustainable methods of water and wastewater management, and water harvesting.
Fire resistance of types of constructions / building components the fire resistance ratings for various types of construction for structural and nonstructural members shall be as given in table 1 of part iv of the nbc, 2005.
Building elements/components such as walls, columns, beams and floors shall have the requisite fire resistance rating in accordance with the accepted standards at tables 2 to 18 of part iv of the nbc.
Note: the sub-station installations shall be carried out in conformity with the local fire regulations and rules there under wherever they are in force. At other places nbc guidelines shall be followed.
Penalties:- violation of the regulations shall be punishable under the provisions regarding unauthorized development.in case of proved deliberate neglect of and/or damage to heritage buildings and heritage precincts, or if the building is allowed to be damaged or destroyed due to neglect or any other reason, in addition to penal action provided under the concerned act, no permission to construct any new building shall be granted on the site if a heritage building or building in a heritage precinct is damaged or pulled down without appropriate permission from commissioner, municipal corporation/ vice chairman, development authority. It shall be open to the heritage conservation committee to consider a request for rebuilding/reconstruction of a heritage building that was unauthorizedly demolished or damaged, provided that the total built-up area in all floors put together in such new construction is not in excess of the total built-up area in all floors put together in the original heritage building in the same form and style in addition to other controls that may be specified.
Thanks and regards,
Pradeep chaudhary
Mob:-[protected]
Ghaziabad Development Authority [GDA] customer support has been notified about the posted complaint.
I want to say that in shastri nagar gda markert shop no. 16 kaa puar vala flat maa SAA hamari shop par silan aur Pani tapak kaha haaa
Humna unsa kha par voo sahi Kar vaa nahi kaha
Jis ka Karan Huma bhut loss hoo Raha haaa
Pls help us